Analysis / Environment / Measurement Tools
Analytical / environmental / measuring instruments are specialized instruments used to analyze specific substances used in scientific research and laboratories. Standard gas used as a research or tester when a specific gas is contained in a can, a colorimeter, spectrophotometer, instrument such as a hydrometer / density meter, nitrogen, etc. used to analyze a specific substance There are gas generators that generate certain gases, UV measuring instruments to make sure that you are irradiating invisible UV rays.
Other Related Pages
- AS ONE Sampling Bag (with 2 Mouth Cock)Specification With two-mouth cock
- NIHON KEIRYOKI KOGYO Hydrometer Heavy LiquidsFor measuring the specific gravity of heavy liquids (heavy liquids)Scale 0.02 Scale Range 1.000~2.000from ₱1,233.09Min. 2 days
- SIBATA SCIENTIFIC TECHNOLOGY SPC Midget Impinger D-2Capacity (mL) 30 Type D-2 typefrom ₱4,929.90Min. 5 days
- Komyo Rikagaku Kogyo / Kitagawa Tube Gas Detector TubeAs ONE Part Number 8-5353-39 Measurable Gas Nitric oxide, elementary oxide Number of Measurements [1 box] 5from ₱1,397.56Min. 9 days
- SANSYO Ostwald viscometer precision typeCompare with the standard sample to determine the relative viscosity. With inspection pass certificate.from ₱13,975.58Min. 6 days
- AS ONE Ubbelohde Viscometer 6327331000 SeriesA kinematic viscometer that does not require surface tension difference correction.Material Borosilicate glass Applicable Standard ISO3105from ₱20,143.10Min. 13 days
- APEL Spectrophotometer PD-303SAchieves high stability even at low wavelengths. The auto zero function can calibrate dark T = 0% and blank liquid T = 100% with one touch. Sufficient measurement is possible with a small sample volume (1.0 mL). The light source lamp boasts a long life of about 2000 hours. Both square cells and r... Read MorePower Supply 100~240V 50/60Hz As ONE Part Number 2-4451-02 Dimension (mm) 270×285×155 Power Plug 2P Range of Wavelength (nm) 340~1000 Mass (kg) 4.8 Wavelength Width (nm) 8 (at all wavelengths) Power Cable (m) About 2 Optical Path Length (mm) Absorption cell / 10 Display Part LCD Light Source Luminance lamp Minimum Scale Wavelength / 1nm Accuracy (nm) Wavelength / ± 2 (at 365/585 and 879nm) Photometric Accuracy ±2%Tfrom ₱160,314.21Min. 13 days
- SIBATA SCIENTIFIC TECHNOLOGY Filter paper clip・Replacement option for A type/B type/C30 type/NW354 type. For low volume *Please select according to the filter paper size.from ₱26,721.78Min. 5 days
- OMI ODOR-AIR SERVICE 9-way distribution activated carbon tank (with curved pipe)By connecting with a 150L pump, you can quickly fill a large number of odor bags.from ₱39,467.97Min. 9 days
- AS ONE Tedlar BagA sampling bag for gas analysis made of vinyl fluoride resin that has excellent resistance to various inorganic gases and organic solvents. Tedlar (R) (vinyl fluoride resin) film has very low gas permeability and adsorptivity, and is suitable as a gas sampling bag. Tedler (R) is a registered trad... Read More
- Toki Sangyo Viscosity Calibration Standard<< Certified by National Institute of Advanced Industrial Science and Technology (with test result guarantee) >> This is a standard solution for calibrating a viscometer standardized by JIS Z 8809. Calibration of various viscometers
- KENIS Gas quantity regulatorBy turning the screw on the top, a constant gas flow rate can be continuously ejected. It can be used by attaching it to an experimental gas can.Material Metal Type Screw adjustment type
- AS ONE Gas Collecting BagSince it uses high quality natural rubber, it is easy to operate and convenient for precise analysis.
- BRAND Disposer (for PS visible light)With an arrow that keeps the light receiving direction constant. The cell window is dented to prevent it from being scratched. The two facing sides are transparent, and the remaining two sides are frosted glass.Optical Path Width (mm) 10 Dimension (mm) 12.5×12.5×45 Measurement Range (nm) 340~900 Standard Deviation (nm) 360≦±0.005 Type For visible light Material PS
- AS ONE Aluminum Bag (with Lever Cock)It is almost impermeable to inorganic gases that are easily permeable to other bags and gases such as methane, PVC monomer, and formaldehyde. It has a 5-layer structure and a wall thickness of 120 μm, so it has excellent mechanical strength. Since it has excellent light-shielding properties, ther... Read MoreMaterial Aluminum laminate type 5-layer structure Sleeve type With one side PTFE (fluororesin) cockfrom ₱1,973.19Min. 2 days
- Toa Keiki Standard Hydrometer for Small 7pcs SetThis is a commonly used hydrometer of JIS B-7525. * Case is not included. * Sold separately.Overall Length (mm) 160 Minimum Scale 0.005
- AS ONE Sampling Bag (with 1 Cock)Material PVDF (polyvinylidene fluoride)from ₱1,233.09Min. 2 days
- NIHON KEIRYOKI KOGYO Baume HydrometerMinimum Scale 1/1 double Baume degree Overall Length (mm) 200
- Kartell Disposable Cell, Cuvettes* 1938/1948: Low form 1940/1941: High form
- NIHON KEIRYOKI KOGYO 10-Degree Baume Heavy Degree MeterIt comes with a certification stamp from the Tokyo Metropolitan Metrology Institute.Minimum Scale 0.1 double baume degree Overall Length (mm) 300
- AS ONE Disposable Cell (Acrylic)The V mark is embossed to identify the measurement direction. For UV region (285-750 nm) measurementOptical Path Length (mm) 10 Dimension (mm) 12.5×12.5×45 Transmission surface 2 Material PMMA (acrylic)
- EGS Simple PVC ClassifierWhen processing and incinerating waste plastic, vinyl chloride can be easily and instantly identified. In addition to vinyl chloride, it exhibits a green flame reaction to substances containing halogen elements (chlorine, bromine, iodine) other than fluorine. Since the fuel is a disposable lighte... Read MoreIncluded Accessories 1 lighter Mass (g) 50 Dimension (mm) 60×23×110 As ONE Part Number 8-5613-01 Specification Judgment operation: about 10 seconds
- A&D Disposable aluminum dishesOption for moisture meter (MS / MX / MF / ML)Trusco Part No. 838-3383 RoHS directive (corresponding to 10 substances) Correspondencefrom ₱2,631.06Min. 2 days
- BRAND Disposable Cuvette (for PMMA Close UV)The standard measurement range is 300 nm or more. The standard deviation of absorbance at 320 nm is 0.004 or less. Since the cell window is recessed, it is not easily scratched. With an arrow to keep the light receiving direction constant. The two facing sides are transparent, and the remaining t... Read MoreOptical Path Width (mm) 10 Dimension (mm) 12.5×12.5×45 Measurement Range (nm) 300~900 Standard Deviation (nm) 320≦±0.004 Type For near UV Material PMMA
- Toa Keiki Standard specific gravity meter Large 19This is a commonly used hydrometer. The large one is used with high accuracy, and the small one is used for a small amount of sample.Overall Length (mm) 300 Material Glass, leadfrom ₱4,929.90Min. 2 days
- Tokyo Glass Kikai (TGK) Gas Sampling Bag Single-MouthMaterial Natural rubber
- Toa Keiki Hydrometer for Heavy Liquid 0-72 Degrees 250mmBaume Range 0-72 degrees Scale Range 1.000~2.000 TGK Part No. 801-53-46-01 Overall Length (mm) About 250 Material Glass, lead Specification Heavy Baume degree: 0 to 72 degrees 1 Scale Once
- AS ONE Glass Cell (Standard Size)As ONE Part Number 1-9737-01 Outer Dimensions (mm) 12.5×12.5×45 Transmission surface 2 sides Capacity (mL) 3.5 Material Optical white plate glass
- Yamato Sangyo Pressure regulator for analyzer NPR-1BBy adopting the NPR system (balance structure), it maintains a stable adjustment pressure despite the one-stage pressure reduction structure. Ideal for gas supply with gas purity of 99.99%. Although NPR-LB and NPR-MB are not balanced, they maintain stable regulating pressure due to their low prim... Read MoreSecondary pressure (MPa) 0.2~0.6 Mass (kg) 1.6 Primary Pressure (MPa) 2~15from ₱20,143.10Min. 2 days
- AS ONE Quartz CellThe bottom is U-shaped. Easy to put in the cell holder and easy to clean.Optical Path Length (mm) 10 Optical Path Width (mm) 10 Dimension (mm) 12.5×12.5×45 Type 2 sides transparent Capacity (mL) 3.5 Material UV quartz glass Measurement Error Within 1% (220nm)from ₱5,752.23Min. 2 days
Filter by categories